DocumentCode :
1047778
Title :
VIII-zero method of measuring power with the quadrant electrometer
Author :
Kouwenhoven, W.B. ; Betz, Paul L.
Author_Institution :
Associate Professor of Electrical Engineering, The Johns Hopkins University.
fYear :
1926
Firstpage :
649
Lastpage :
667
Abstract :
This paper describes a zero method of measuring power by means of the quadrant electrometer developed by the authors, and which we believe to be new. Zero deflection of the electrometer is obtained by opposing the torque produced by the a-c. load by means of a counter torque set up by continuous potentials introduced into the electrometer circuit. The continuous potentials required are small in value and easily handled. We have derived the equations that apply to the method and checked their correctness by experimental observations, on resistance, capacity, and inductive circuits.
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1926.5061259
Filename :
5061259
Link To Document :
بازگشت