• DocumentCode
    1047779
  • Title

    Resolution of fiber-optic faceplate image-intensifier tubes as a function of magnification

  • Author

    Dolon, Paul J.

  • Author_Institution
    Varo Electron, Devices, Inc., Garland, Tex.
  • Volume
    21
  • Issue
    6
  • fYear
    1974
  • fDate
    6/1/1974 12:00:00 AM
  • Firstpage
    376
  • Lastpage
    377
  • Abstract
    The resolution capability of image intensifiers is customarily assumed as proportional to the magnification of the tube. An equation is presented to calculate resolution a priori as a function of magnification, applicable to tubes with fiber-optic faceplates. in addition, a method is suggested to improve the resolution capability of multistage tubes.
  • Keywords
    Costs; Design methodology; Diodes; Electron devices; Electron optics; Electron tubes; Equations; Image intensifiers; Image resolution; Optical fibers;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1974.17931
  • Filename
    1477746