DocumentCode
1049199
Title
Development of EHV Cross-Linked Polyethylene Insulated Power Cables
Author
Yoda, B. ; Muraki, K.
Author_Institution
Hitachi Cable, Ltd.
Issue
2
fYear
1973
fDate
3/1/1973 12:00:00 AM
Firstpage
506
Lastpage
513
Abstract
To apply cross-linked polyethylene for EHV cable insulation, several cables are designed, and manufactured and their characteristics are measured. By manufacturing, normal cross-linked polyethylene are used for comparison together with special cross-linked polyethylene insulations which have been newly developed. It is found that non-carbon filled and voltage-stabilized insulations possess excellent properties in corona and treeing deterioration resistance, and electrical breakdown strength which indicate the possibility of application these cables to real service. Problems and aspects of plastic-insulated power cables for higher voltage grades, such as 275kV class, are discussed.
Keywords
Breakdown voltage; Cable insulation; Corona; Dielectrics and electrical insulation; Electric resistance; Electrical resistance measurement; Manufacturing; Polyethylene; Power cables; Trees - insulation;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1973.293750
Filename
4075104