• DocumentCode
    1049199
  • Title

    Development of EHV Cross-Linked Polyethylene Insulated Power Cables

  • Author

    Yoda, B. ; Muraki, K.

  • Author_Institution
    Hitachi Cable, Ltd.
  • Issue
    2
  • fYear
    1973
  • fDate
    3/1/1973 12:00:00 AM
  • Firstpage
    506
  • Lastpage
    513
  • Abstract
    To apply cross-linked polyethylene for EHV cable insulation, several cables are designed, and manufactured and their characteristics are measured. By manufacturing, normal cross-linked polyethylene are used for comparison together with special cross-linked polyethylene insulations which have been newly developed. It is found that non-carbon filled and voltage-stabilized insulations possess excellent properties in corona and treeing deterioration resistance, and electrical breakdown strength which indicate the possibility of application these cables to real service. Problems and aspects of plastic-insulated power cables for higher voltage grades, such as 275kV class, are discussed.
  • Keywords
    Breakdown voltage; Cable insulation; Corona; Dielectrics and electrical insulation; Electric resistance; Electrical resistance measurement; Manufacturing; Polyethylene; Power cables; Trees - insulation;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1973.293750
  • Filename
    4075104