DocumentCode :
1049314
Title :
Nonlinear Theory of Turboalternators Part II. Load Dependent Synchronous Reactances
Author :
Fuchs, Ewald F. ; Erdelyi, Edward A.
Author_Institution :
University of Colorado
Issue :
2
fYear :
1973
fDate :
3/1/1973 12:00:00 AM
Firstpage :
592
Lastpage :
599
Abstract :
The method in Ref. [1] is used to determine synchronous reactances for the turbogenerator at operating conditions in Part I [2]. The influence of saturation on the direct and quadrature reactances is studied and the difficulties caused by linear parameters in nonlinear theory are discussed. A modified phasor-diagram taking the small angles ¿d and ¿q into account is developed. The results are given for a Westinghouse Electric Corp. 200 MVA, 15 kV, wye-connected, four-pole, 50 Hz generator. Available test data are compared with computations.
Keywords :
Alternators; Machinery; Power & Energy Society; Power engineering and energy; Power engineering computing; Power system analysis computing; Power systems; Printing; Testing; Turbogenerators;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1973.293762