• DocumentCode
    1049718
  • Title

    Investigation of Subsynchronous Resonance With VSC-Based HVDC Transmission Systems

  • Author

    Prabhu, Nagesh ; Padiyar, K.R.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Nitte Meenakshi Inst. of Technol., Bangalore
  • Volume
    24
  • Issue
    1
  • fYear
    2009
  • Firstpage
    433
  • Lastpage
    440
  • Abstract
    The HVDC converter control can destabilize torsional modes of nearby turbogenerators. The first experience of HVDC-turbine generator torsional interaction was observed in 1977 during field tests at Square Butte. The development of power semiconductors, specially insulated-gate bipolar transistors and gate turnoff thyristors (GTOs) has led to the small power HVDC transmission based on voltage-source converters (VSCs). The self-commutated VSC-based HVDC installations have several advantages compared to conventional HVDC-based online-commutated current source converter. The main objective of this paper is to investigate and present the detailed analysis of subsynchronous resonance (SSR), arising from a VSC-based HVDC system connected close to generating units. The analysis considers different operating modes of the converters. Based on a case study, it is shown that the dc voltage control mode of VSC operation (rectifier/inverter) close to the generator units can contribute positive damping in the torsional-mode frequency range of interest. The investigations of SSR with VSC-based HVDC is carried out based on linear (damping torque and eigenvalue) analysis and nonlinear transient simulation. While the damping torque, eigenvalue analysis, and controller design are based on the D-Q model, the transient simulation considers the D-Q model and the three-phase detailed model of VSC using switching functions. The influence of the operating modes of the converters and effects of some important parameters, such as effective short circuit ratio and generator rating are investigated.
  • Keywords
    HVDC power transmission; eigenvalues and eigenfunctions; power transmission control; subsynchronous resonance; voltage control; D-Q model; VSC-based HVDC transmission systems; controller design; damping torque; dc voltage control; effective short circuit ratio; eigenvalue analysis; generator rating; linear analysis; nonlinear transient simulation; positive damping; subsynchronous resonance; switching functions; torsional-mode frequency range; transient simulation; voltage-source converters; Analytical models; Converters; Damping; Eigenvalues and eigenfunctions; HVDC transmission; Power conversion; Resonance; Testing; Transient analysis; Turbogenerators; Damping torque; HVDC; eigenvalue analysis; parameter optimization; transient simulation; voltage-source converters (VSCs);
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2008.2005878
  • Filename
    4729814