    Transient Eerformance of 3-Phase Inductor-Type Synchronous Generator II-Uusymmetrical Short Circuits

  • Author

    Dash, P.K.

  • Author_Institution
    Regional Engineering College
  • Issue
    3
  • fYear
    1973
  • fDate
    5/1/1973 12:00:00 AM
  • Firstpage
    1157
  • Lastpage
    1161
  • Abstract
    The line-to-ground short-circuit case of an inductor-type synchronous generator is solved. Modified a, ß, 0 components have been used to formulate the basic differential equations of the alternator, which can be solved approximately to yield short-circuit currents. As compared to conventional synchronous machines these types of generators have lower short-circuit currents, and higher transient reactances. The short-circuit currents also decay at a comparatively faster rate than the normal synchronous machines.
  • Keywords
    Alternators; Circuits; Differential equations; Inductance; Inductors; Machine windings; Rotors; Synchronous generators; Synchronous machines; Voltage;