• DocumentCode
    1050426
  • Title

    Reactance-Shift Light Load and Inductive Load Adjustments for Watthour Meters

  • Author

    Graefnitz, R.F.

  • Author_Institution
    Duncan Electric Company, Inc.
  • Issue
    4
  • fYear
    1973
  • fDate
    7/1/1973 12:00:00 AM
  • Firstpage
    1392
  • Lastpage
    1398
  • Abstract
    Description of newly designed watthour meter light load and inductive load adjustments having only one moving part in each. A conductive plate, here-tofore movable, now with three circuits, is fixed in position. The two outer circuits, oppositely displaced from center, are loaded by coils through which moves a magnetic screw for adjusting light load. The phasing adjustment is a similar screw, moving in a coil that loads the center circuit, simultaneously changing the gap in a magnetic circuit which picks up leakage flux for torque compensation and is located to avoid differential shunting of the side arm gaps.
  • Keywords
    Assembly; Costs; Current measurement; Electromagnetic measurements; Instruments; Manufacturing processes; Power measurement; Reactive power; Testing; Watthour meters;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1973.293547
  • Filename
    4075221