DocumentCode :
1050738
Title :
Influence of Unbalanced Currents on the Design and Operation of Large Turbine Generators
Author :
Linkinhoker, C.L. ; Schmitt, N. ; Winchester, R.L.
Author_Institution :
Generator Department General Electric Company
Issue :
5
fYear :
1973
Firstpage :
1597
Lastpage :
1604
Abstract :
The influence ofunbalanced currents onthe design and operation of large turbine generators is described beginning with a summary of factory unbalanced current tests. Generator design considerations are discussed, including: rotor design features and practice, effects of short time and continuous unbalanced loading, and influence of unbalanced fault capability on major generator parameters. These considerations plus a summary of operating experience confirm that provision for unbalanced fault capability should not be an overriding consideration in the design of large generators, and support the need for industry standards revision.
Keywords :
Current distribution; Electromagnetic heating; Heat transfer; Production facilities; Proposals; Rotors; Stator windings; Synchronous generators; Testing; Turbines;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1973.293707
Filename :
4075253
Link To Document :
بازگشت