DocumentCode :
1050940
Title :
Audible-Noise Reduction by Bundle Geometry Optimization
Author :
Comber, M.O. ; Zaffanella, L.E.
Author_Institution :
General Electric Company
Issue :
5
fYear :
1973
Firstpage :
1782
Lastpage :
1791
Abstract :
Audible noise due to foul-weather corona on multi-conductor bundles for EHV and UHV transmission can be reduced by proper choice of the bundle geometry. Laboratory tests have been carried out to determine the noise generation of individual subconductor in a bundle. Based on the results of these tests, the relative audible-noise performance of several different con-figurations of 4-, 6-, and 8-conductor bundles are determined. A comparison is made between computed and measured performances for a 6-conductor bundle.
Keywords :
Acoustic noise; Conductors; Geometry; Laboratories; Noise generators; Noise reduction; Performance evaluation; Rain; Spraying; System testing;