Title :
A method for ultrasensitive magnetostriction measurement
Author :
Drosdziok, Siegfried ; Wessel, Kurt
Author_Institution :
Institut der Universität Cologne, Cologne, West Germany.
fDate :
3/1/1973 12:00:00 AM
Abstract :
Determination of Joule magnetostriction by the method of tensile strain measurement has a lower limit of about 10-6because of error strains clue to magnetostatic forces and changes in temperature. It is shown that these disturbances can be eliminated by measuring shear strains induced in thin-walled tubes by helical magnetic fields. By a resonance method, the measurement of the magnetostriction constant can be made down to 10-13.
Keywords :
Magnetic measurements; Magnetostriction; Force measurement; Magnetic field induced strain; Magnetic field measurement; Magnetic resonance; Magnetostatics; Magnetostriction; Strain measurement; Temperature; Tensile strain; Thin wall structures;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1973.1067567