• DocumentCode
    1052026
  • Title

    Direct Conductor-Cooling of Large Steam Turbine-Generator 4-Pole Rotors

  • Author

    Armor, A.F. ; Gibney, J.J.

  • Author_Institution
    General Electric Company
  • Issue
    2
  • fYear
    1974
  • fDate
    3/1/1974 12:00:00 AM
  • Firstpage
    477
  • Lastpage
    486
  • Abstract
    An increasing number of 4-pole steam turbine-driven generators are being ordered each year by utilities and with steadily increasing unit ratings. This paper discusses rotor cooling for 4-pole generators and shows that gas conductor cooling can be applied to unit sizes far in excess of those now being built. In particular, the radial flow system of cooling, very successfully applied to date, has capability for steam turbine-generator rotor cooling for units forecast for the 1980´s.
  • Keywords
    Conductors; Coolants; Cooling; Copper; Hydrogen; Industrial economics; Manufacturing; Rotors; Surface discharges; Teeth;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1974.293994
  • Filename
    4075382