DocumentCode :
1052193
Title :
Area Effect of Electrical Breakdown in Compressed SF6
Author :
Nitta, T. ; Yamada, N. ; Fujiwara, Y.
Author_Institution :
Mitsubishi Electric Corporation
Issue :
2
fYear :
1974
fDate :
3/1/1974 12:00:00 AM
Firstpage :
623
Lastpage :
629
Abstract :
This paper presents experimental results on the statistical properties of ac and dc breakdown field strength of compressed SF6. The experiment is performed on four gaps of different electrode area, ranging from 0.2 cm2 to 3000 cm2. Patterns of breakdown characteristics are classified into four categories depending on the type of distribution and the characteristics of conditioning effect. The criterion of the transition of these categories are discussed quantitatively.
Keywords :
Coaxial components; Electric breakdown; Electrodes; Engine cylinders; Rough surfaces; Steel; Sulfur hexafluoride; Surface finishing; Surface roughness; Testing;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1974.294024