• DocumentCode
    1053140
  • Title

    Dynamic Stability Tests on a 733 MVA Generator at Kincaid Station

  • Author

    Bingen, P. ; Landgren, G.L. ; Keay, F.W. ; Raczkowski, C.

  • Author_Institution
    Commonwealth Edison Company
  • Issue
    5
  • fYear
    1974
  • Firstpage
    1328
  • Lastpage
    1334
  • Abstract
    Field tests have confirmed that properly designed excitation control can extend the dynamic stablity range of machines. A new type of stability compensation, described in a companion paper, has been successfully applied. Application of this new equipment is made possible by the installation of a modern solid state high performance excitation system. Field tests conducted on a 733 mVA generator have shown that this compensation, applied to the excitation system, is effective in extending the stability limit of the machine beyond the limit obtainable without compensation.
  • Keywords
    Control systems; Impedance; Low voltage; Manufacturing; Regulators; Sliding mode control; Solid state circuits; Stability; System testing; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1974.293857
  • Filename
    4075496