Complete Parameter Identification of Large Induction Machines From No-Load Acceleration–Deceleration Tests
Author
Babau, Radu ; Boldea, Ion ; Miller, T.J.E. ; Muntean, Nicolae
Author_Institution
Varspeed Hydro Ltd., Timisoara
Volume
54
Issue
4
fYear
2007
Firstpage
1962
Lastpage
1972
Abstract
This paper introduces an offline deterministic method for identification of inertia moment, mechanical losses, and electrical parameters for large induction machines, based on direct-on-line starting and natural slowdown tests, performed under no-load conditions. The static characteristic of absorbed power is used for the validation of results. Complete experimental results for a 6-kV four-pole 7500-kW machine are presented. The method brings significant cost savings for testing large induction machines.
Keywords
asynchronous machines; machine testing; parameter estimation; International Electrotechnical Commission; electrical parameter; inertia moment; large induction machine; mechanical losses; no-load acceleration test; no-loaddeceleration test; offline deterministic method; parameter identification; power 7500 kW; voltage 6 kV; Costs; Design automation; IEC standards; Induction machines; Kinetic energy; Kinetic theory; Life estimation; Parameter estimation; Steady-state; Testing; International Electrotechnical Commission (IEC) standards; large induction machines; parameter identification; testing;