DocumentCode :
1056453
Title :
A Three-Phase UPS That Complies With the Standard IEC 62040-3
Author :
Botterón, Fernando ; Pinheiro, Humberto
Author_Institution :
Univ. Nacional de Misiones, Obera
Volume :
54
Issue :
4
fYear :
2007
Firstpage :
2120
Lastpage :
2136
Abstract :
This paper proposes a down-sampled discrete-time internal-model-based controller in the synchronous reference frame with a reduced number of poles. This controller is suitable for three-phase pulsewidth modulation inverters with output transformer for double-conversion uninterruptible power supply applications. It is demonstrated that the use of a down-sampled rate and fewer poles in the internal model results in a number of benefits, among which are the following: 1) improvement of the transient response; 2) increase of the stability margin of the closed-loop system; 3) a straightforward implementation in fixed-point digital signal processor (DSP) and microcontroller implementation as well as a reduction of the required memory space; and 4) a simple solution for the saturation of the output transformer. As a result, it is possible to obtain output voltages with reduced total harmonic distortion while ensuring good transient performance for both linear and nonlinear loads. To confirm the advantages claimed for the proposed synchronous reference dq frame internal-model-based controller and to demonstrate the steady-state and transient performance under the test conditions of the International electrotechnical commission standard 62040-3, the experimental results from a 10-kVA space-vector-modulated three-phase inverter, which is fully controlled by a DSP TMS320F241, are presented.
Keywords :
IEC standards; PWM invertors; controllers; uninterruptible power supplies; closed-loop system; discrete-time control; double-conversion uninterruptible power supply; down-sampled discrete-time internal-model-based controller; fixed-point digital signal processor; internal model principle; microcontroller; output transformer; power transformers; reduced total harmonic distortion; space-vector-modulated three-phase inverter; standard IEC 62040-3; synchronous reference frame; three-phase UPS; three-phase pulsewidth modulation inverters; transient response; Circuit faults; Digital signal processing; IEC standards; Power system modeling; Pulse inverters; Pulse modulation; Pulse transformers; Pulse width modulation inverters; Pulsed power supplies; Uninterruptible power systems; Digital control; discrete-time control; internal model principle; power transformers; uninterruptible power systems (UPSs);
fLanguage :
English
Journal_Title :
Industrial Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0046
Type :
jour
DOI :
10.1109/TIE.2007.894782