• DocumentCode
    1057207
  • Title

    System identification based on closed-loop step response data

  • Author

    Wang, L. ; Cluett, W.R.

  • Author_Institution
    Dept. of Chem. Eng., Toronto Univ., Ont., Canada
  • Volume
    141
  • Issue
    2
  • fYear
    1994
  • fDate
    3/1/1994 12:00:00 AM
  • Firstpage
    107
  • Lastpage
    110
  • Abstract
    This paper presents a new identification algorithm for processes operating in closed-loop. The algorithm involves fitting two Laguerre models directly to the control signal and the process output signal generated by a step change in the setpoint. The algorithm does not require any prior assumptions about the structure of the process model. The method generates an estimate of the process model in the frequency domain, and then transforms this frequency domain estimate into a continuous-time Laguerre model. Simulation results are used to illustrate the accuracy of the algorithm
  • Keywords
    closed loop systems; frequency-domain analysis; identification; step response; Laguerre models; closed-loop step response; frequency domain; setpoint; step change; system identification;
  • fLanguage
    English
  • Journal_Title
    Control Theory and Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2379
  • Type

    jour

  • DOI
    10.1049/ip-cta:19949971
  • Filename
    278023