DocumentCode
1057311
Title
VXD3: the SLD vertex detector upgrade based on a 307 MPixel CCD system
Author
Brau, James E.
Author_Institution
Oregon Univ., Eugene, OR, USA
Volume
43
Issue
3
fYear
1996
fDate
6/1/1996 12:00:00 AM
Firstpage
1107
Lastpage
1112
Abstract
The SLD upgrade CCD vertex detector (VXD3) is described. Its 307 million pixels are assembled from 96 3.2 Mpixel CCDs of 13 cm2 each. The system has evolved from the pioneering CCD vertex detector VXD2, which has operated in SLD since 1992. The CCDs of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolution in all three co-ordinates. Significant improvements are achieved with VXD3 in impact parameter resolution (about a factor of two) and acceptance (~20%) through optimized geometry and reduced, material. New readout electronics have been developed for this system
Keywords
charge-coupled devices; detector circuits; nuclear electronics; position sensitive particle detectors; semiconductor counters; 5 micron; Be; CCD vertex detector; SLD vertex detector; VXD3; acceptance; impact parameter resolution; readout electronics; Assembly; Charge coupled devices; Collaboration; Detectors; Extraterrestrial measurements; Geometry; Linear accelerators; Polarization; Superluminescent diodes; Time measurement;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.506646
Filename
506646
Link To Document