DocumentCode
1057321
Title
Irradiation tests of double-sided silicon strip detectors with a special guard ring structure
Author
Abt, I. ; Andricek, L. ; Bauer, C. ; Fox, H. ; Halley, A. ; Kroha, H. ; Richter, R.H. ; Riechmann, K. ; Rietz, M. ; Rübsam, R. ; Seywerd, H. ; Denis, R. St ; Baumann, I. ; Knöpfle, K.T.
Author_Institution
Max-Planck-Inst. fur Phys., Munchen, Germany
Volume
43
Issue
3
fYear
1996
fDate
6/1/1996 12:00:00 AM
Firstpage
1113
Lastpage
1118
Abstract
The results of the first irradiation tests of newly designed silicon microstrip detectors performed with 21 MeV protons at the Max-Planck-Institut in Heidelberg are presented. The detectors were developed and produced by the semiconductor laboratory of the Max-Planck-Institut in Munich. Novel guard ring structures allow operation of the detectors at voltages exceeding 300 V
Keywords
proton effects; silicon radiation detectors; 21 MeV; 300 V; Si; Si strip detectors; double-sided; guard ring; proton irradiation; voltage; Copper; Detectors; Implants; Large Hadron Collider; Mesons; Microstrip; Physics; Silicon; Strips; Testing;