• DocumentCode
    1057642
  • Title

    Precision of radio reflector surfaces adjusted from theodolite-tape measurements

  • Author

    Greve, A. ; Morris, D. ; Johansson, L.E.B. ; Whyborn, N.D. ; Gluiber, A.

  • Author_Institution
    IRAM, Granada, Spain
  • Volume
    141
  • Issue
    1
  • fYear
    1994
  • fDate
    2/1/1994 12:00:00 AM
  • Firstpage
    23
  • Lastpage
    29
  • Abstract
    The authors analyse the surface errors of five reflectors of millimetre and centimetre wavelength radiotelescopes which were initially adjusted from theodolite-tape measurements. The initial adjustment of the millimetre-wavelength reflectors was later measured more precisely by radio holography. All reflectors had systematic ring-like zone deviations and superimposed random deviations of Gaussian distribution of which the dispersion increases towards the reflector rim. Such spatially nonuniform surface errors are typical for adjustments from theodolite-tape measurements
  • Keywords
    measurement errors; microwave holography; radiotelescopes; reflector antennas; surface topography measurement; Gaussian distribution; centimetre wavelength; millimetre-wavelength; radio holography; radio reflector surfaces precision; radiotelescopes; ring-like zone deviations; superimposed random deviations; surface errors; theodolite-tape measurements;
  • fLanguage
    English
  • Journal_Title
    Microwaves, Antennas and Propagation, IEE Proceedings
  • Publisher
    iet
  • ISSN
    1350-2417
  • Type

    jour

  • DOI
    10.1049/ip-map:19949710
  • Filename
    278085