• DocumentCode
    1059396
  • Title

    Comparison of precision AC and DC measurements with the quantized Hall resistance

  • Author

    Melcher, Jiirgen ; Warnecke, Peter ; Hanke, Riidiger

  • Author_Institution
    Phys.-Tech. Bundesanstalt, Braunschweig, Germany
  • Volume
    42
  • Issue
    2
  • fYear
    1993
  • fDate
    4/1/1993 12:00:00 AM
  • Firstpage
    292
  • Lastpage
    294
  • Abstract
    The quantized Hall resistance RH(2) is compared with various 100-kΩ AC resistance standards. The measurements were performed with an 8:1 four terminal-pair divider bridge at a frequency of 1592 Hz. The 100-kΩ resistances were previously calibrated using the PTB ohm chain starting at the DC side with the same quantum Hall resistance. The mean AC value of the quantized Hall resistance was 12906.4017 Ω with a relative standard deviation of 0.14×10-6 after ten measurements. The total uncertainty, which is mainly determined by the AC bridge, was about 3×10-6
  • Keywords
    bridge instruments; electric resistance measurement; measurement standards; quantum Hall effect; 100 kohm; 1592 Hz; AC bridge; AC resistance standards; DC measurements; PTB ohm chain; four terminal-pair divider bridge; quantized Hall resistance; Bridge circuits; Bridges; Electrical resistance measurement; Frequency conversion; Frequency measurement; Hall effect; Measurement standards; Performance evaluation; Resistors; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.278568
  • Filename
    278568