DocumentCode :
1060823
Title :
A method to compute transients in synchronous generators using frequency domain methods
Author :
Bedford, T.J. ; Jack, A.G.
Author_Institution :
N.E.I. Parsons Ltd., Newcastle upon Tyne, UK
Volume :
3
Issue :
2
fYear :
1988
fDate :
6/1/1988 12:00:00 AM
Firstpage :
367
Lastpage :
374
Abstract :
A method to calculate the transient response of a synchronous machine using fast Fourier transforms is presented. The machine is described by its operational inductances defined in the frequency domain. The use of the method for solving transients where the post-fault form of the voltages is known (such as a sudden short circuit) and where it is unknown (such as a line switch) is described. The method is validated against closed-form solutions and against the results from a conventional time-stepping program which uses equivalent circuits
Keywords :
fast Fourier transforms; frequency-domain analysis; synchronous generators; transient response; closed-form solutions; equivalent circuits; fast Fourier transforms; frequency domain methods; post fault voltages; synchronous generators; time-stepping program; transient response; Closed-form solution; Equivalent circuits; Fast Fourier transforms; Frequency domain analysis; Switches; Switching circuits; Synchronous generators; Synchronous machines; Transient response; Voltage;
fLanguage :
English