Motion Artifacts of Extended High Frame Rate Imaging
Author :
Wang, Jing ; Lu, Jian-Yu
Author_Institution :
Toledo Univ., Toledo
Volume :
54
Issue :
7
fYear :
2007
fDate :
7/1/2007 12:00:00 AM
Firstpage :
1303
Lastpage :
1315
Abstract :
Based on the high frame rate (HFR) imaging method developed in our lab, an extended high frame rate imaging method with various transmission schemes was developed recently. In this method, multiple, limited- diffraction array beams or steered plane wave transmissions are used to increase image resolution and field of view as well as to reduce sidelobes. Furthermore, the multiple, limited-diffraction array beam transmissions can be approximated with square-wave aperture weightings, allowing one or two transmitters to be used with a multielement array transducer to simplify imaging systems. By varying the number of transmissions, the extended HFR imaging method allows a continuous trade-off between image quality and frame rate. Because multiple transmissions are needed to obtain one frame of image for the method, motion could cause phase misalignment and thus produce artifacts, reducing image contrast and resolution and leading to an inaccurate clinical interpretation of images. Therefore, it is important to study how motion affects the method and provide a useful guidance of using the method properly in various applications. In this paper, computer simulations, in vitro and in vivo experiments were performed to study the effects of motion on the method in different conditions. Results show that a number of factors may affect the motion effects. However, it was found that the extended HFR imaging method is not sensitive to the motions commonly encountered in the clinical applications, as is demonstrated by an in vivo heart experiment, unless the number of transmissions is large and objects are moving at a high velocity near the surface of a transducer.
Keywords :
biomedical ultrasonics; cardiology; image motion analysis; image resolution; medical image processing; ultrasonic transducers; extended high frame rate imaging; heart; image contrast; image resolution; motion artifacts; multielement array transducer; multiple limited-diffraction array beams; phase misalignment; square-wave aperture weightings; steered plane wave transmissions; Apertures; Application software; Computer simulation; Diffraction; High-resolution imaging; Image quality; Image resolution; In vivo; Transducers; Transmitters; Algorithms; Artifacts; Image Enhancement; Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography; Video Recording;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2007.391
Filename :
4277147
Link To Document :
بازگشت