DocumentCode
1065073
Title
The Discharge-Repetition Rate in Cavities in Epoxy Resin, Polyethylene, and Mica under Alternating Voltage Conditions
Author
Megahed, Ibrahim Y.
Author_Institution
Department of Electrical Engineering, Faculty of Engineering, University of Tripoli, Tripoli, Libya
Issue
2
fYear
1975
fDate
6/1/1975 12:00:00 AM
Firstpage
69
Lastpage
74
Abstract
An investigation into the repetition rate and magnitude of internal discharges in artificial cavities in epoxy resin, polyethylene, and mica, using a multichannel pulse height analyzer is described. The effect of time of voltage application, cavity dimensions, and location, and opening the cavity or ventilating it in air and nitrogen has been studied. The results indicate that it is the discharge quantity rather than the discharge energy measured externally in the largest pulse that is important. It is suggested that in order to correlate discharge damage with discharge activity, it is essential to measure continuously both discharge magnitudes and repetition rates.
Keywords
Circuit testing; Dielectric measurements; Electrodes; Epoxy resins; Fault location; Polyethylene; Pulse amplifiers; Pulse measurements; Pulse transformers; Voltage;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/TEI.1975.297865
Filename
4080286