• DocumentCode
    1065073
  • Title

    The Discharge-Repetition Rate in Cavities in Epoxy Resin, Polyethylene, and Mica under Alternating Voltage Conditions

  • Author

    Megahed, Ibrahim Y.

  • Author_Institution
    Department of Electrical Engineering, Faculty of Engineering, University of Tripoli, Tripoli, Libya
  • Issue
    2
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    69
  • Lastpage
    74
  • Abstract
    An investigation into the repetition rate and magnitude of internal discharges in artificial cavities in epoxy resin, polyethylene, and mica, using a multichannel pulse height analyzer is described. The effect of time of voltage application, cavity dimensions, and location, and opening the cavity or ventilating it in air and nitrogen has been studied. The results indicate that it is the discharge quantity rather than the discharge energy measured externally in the largest pulse that is important. It is suggested that in order to correlate discharge damage with discharge activity, it is essential to measure continuously both discharge magnitudes and repetition rates.
  • Keywords
    Circuit testing; Dielectric measurements; Electrodes; Epoxy resins; Fault location; Polyethylene; Pulse amplifiers; Pulse measurements; Pulse transformers; Voltage;