Title :
Off-resonance transformer charging for 250-kV water blumlein
Author :
Cook, Edward G. ; Reginato, Louis L.
Author_Institution :
University of California, Livermore, CA
fDate :
10/1/1979 12:00:00 AM
Abstract :
An off-resonance transformer for charging a 250-kV Blumlein system provides a viable alternative to other charging schemes by permitting the use of conventional thyratrons. Such a transformer must have reliability, a reasonable voltage stepup, and a nonreversing primary current. This paper presents the analysis, design, and performance data for such a transformer. The strong interrelationship between transformer design and Blumlein requirements necessitates that Blumlein description and design criterion be briefly presented prior to transformer design such that transformer load requirements be defined.
Keywords :
Acceleration; Breakdown voltage; Coaxial cables; Electric breakdown; Electron beams; Oil insulation; Safety; Surface charging; Switches; Thyratrons;
Journal_Title :
Electron Devices, IEEE Transactions on
DOI :
10.1109/T-ED.1979.19640