DocumentCode
1065506
Title
Eight Tesla Superconducting Solenoid Magnet for the Magnetic Circular Dichroism Study
Author
Chang, C.H. ; Hwang, C.S. ; Lin, F.Y. ; Huang, M.H. ; Chen, H.H. ; Jan, J.C. ; Yang, C.S. ; Lin, H.J.
Author_Institution
Inst. of Nat. Synchrotron Radiat. Res. Center, Hsinchu
Volume
17
Issue
2
fYear
2007
fDate
6/1/2007 12:00:00 AM
Firstpage
2204
Lastpage
2207
Abstract
This study describes the design and testing of a superconducting solenoid magnet for soft X-ray magnetic circular dichroism (SXMCD) experiments at the National Synchrotron Radiation Research Center (NSRRC). The superconducting solenoid magnet provides an uniform field of up to 8 T in a bore of 55 mm in diameter and 0.5 m long. The superconducting solenoid is operated in a 4.5-K liquid helium bath for reducing the vibration level during the experiments. The magnet and its cryostat are optimized to prevent magnet quenching and lower liquid helium consumption. The magnet quench test and magnetic field measurements are also performed.
Keywords
cryostats; magnetic circular dichroism; superconducting magnets; cryostat; liquid helium bath; magnet quench test; magnetic field measurements; magnetic flux density 8 T; soft X-ray magnetic circular dichroism experiments; superconducting solenoid magnet; temperature 4.5 K; Boring; High temperature superconductors; Magnetic field measurement; Soft magnetic materials; Solenoids; Superconducting coils; Superconducting filaments and wires; Superconducting magnets; Synchrotron radiation; Testing; Magnetic circular dichroism; solenoid; superconducting;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2007.897806
Filename
4277320
Link To Document