• DocumentCode
    1068067
  • Title

    DC septum magnets and their leakage field effects on an electron beam in the SPring-8 storage ring

  • Author

    Tsumaki, K. ; Shimada, T. ; Kajimoto, K. ; Yonehara, H. ; Kumagai, N.

  • Author_Institution
    Japan Synchrotron Radiat. Res. Inst., Hyogo, Japan
  • Volume
    14
  • Issue
    2
  • fYear
    2004
  • fDate
    6/1/2004 12:00:00 AM
  • Firstpage
    433
  • Lastpage
    436
  • Abstract
    We fabricated improved DC septum magnets that have smaller leakage fields for continuous beam injection. We changed the shape of the coil and placed field clamps at both ends of the magnets. We increased the thickness of the septum-plane shields and extended them to the field clamps. Leakage fields were measured and the effect they had on an electron beam during injection was studied. After reducing the leakage fields, the orbit changes during injection were less than the beam sizes, which satisfied the requirements for continuous beam injection.
  • Keywords
    accelerator magnets; electromagnets; electron accelerators; electron beam effects; magnetic fields; magnetic leakage; particle beam injection; storage rings; synchrotron radiation; 8 GeV; DC septum magnets; SPring-8 storage ring; continuous beam injection; electron beam; field clamps; leakage field effects; septum-plane shields; synchrotron radiation source; top up operation; Atomic measurements; Clamps; Coils; Electron beams; Extraterrestrial measurements; Magnetic field measurement; Magnets; Shape; Storage rings; Synchrotron radiation; Leakage field; septum magnet; synchrotron radiation source; top up operation;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2004.829689
  • Filename
    1324826