DocumentCode :
1068310
Title :
Effect of Avalanche Space Charge Field on the Calculation of Corona Onset Voltage
Author :
Parekh, H. ; Srivastava, K.D.
Author_Institution :
Department of Electrical Engineering University of Waterloo Waterloo, Ontario, Canada
Issue :
4
fYear :
1979
Firstpage :
181
Lastpage :
192
Abstract :
Many researchers have suggested that the space charge field of the primary electron avalanche should not be neglected in calculating the corona onset voltage based on the streamer criterion. Some researchers consider only the space charge field of the positive ions created during the avalanche growth, while others consider only the space charge field of the electrons at the head of the avalanche. The authors suggest that both space charge fields should be considered in calculating the corona onset voltage. Computer programs are written to calculate the breakdown voltage (for uniform field: parallel-plane geometry) and corona onset voltage (for non-uniform field: point-to-plane geometry). The space charge fields of both the positive ions and the electrons are considered in the calculations. Results are obtained for air and SF6 for a wide range of geometrical parameters and gas pressures. The results indicate that the effect of space charge fields is to reduce the corona onset voltage (or breakdown voltage in uniform field geometry) by less than 5%.
Keywords :
Breakdown voltage; Clouds; Computational geometry; Concurrent computing; Corona; Electrons; Gases; Ionization; Space charge; Sulfur hexafluoride;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/TEI.1979.298171
Filename :
4080641
Link To Document :
بازگشت