• DocumentCode
    1068660
  • Title

    Rapid Dynamic Image Registration of the Beating Heart for Diagnosis and Surgical Navigation

  • Author

    Huang, Xishi ; Ren, Jing ; Guiraudon, Gerard ; Boughner, Derek ; Peters, Terry M.

  • Author_Institution
    Imaging Res. Labs., Robarts Res. Inst., London, ON, Canada
  • Volume
    28
  • Issue
    11
  • fYear
    2009
  • Firstpage
    1802
  • Lastpage
    1814
  • Abstract
    Dynamic cardiac magnetic resonance imaging (MR) and computed tomography (CT) provide cardiologists and cardiac surgeons with high-quality 4-D images for diagnosis and therapy, yet the effective use of these high-quality anatomical models remains a challenge. Ultrasound (US) is a flexible imaging tool, but the US images produced are often difficult to interpret unless they are placed within their proper 3-D anatomical context. The ability to correlate real-time 3-D US volumes (RT3D US) with dynamic MR/CT images would offer a significant contribution to improve the quality of cardiac procedures. In this paper, we present a rapid two-step method for registering RT3D US to high-quality dynamic 3-D MR/CT images of the beating heart. This technique overcomes some major limitations of image registration (such as the correct registration result not necessarily occurring at the maximum of the mutual information (MI) metric) using the MI metric. We demonstrate the effectiveness of our method in a dynamic heart phantom (DHP) study and a human subject study. The achieved mean target registration error of CT+US images in the phantom study is 2.59 mm. Validation using human MR/US volumes shows a target registration error of 1.76 mm. We anticipate that this technique will substantially improve the quality of cardiac diagnosis and therapies.
  • Keywords
    biomedical MRI; biomedical ultrasonics; cardiology; computerised tomography; error analysis; image registration; medical image processing; phantoms; beating heart; computed tomography; diagnosis; dynamic cardiac magnetic resonance imaging; dynamic heart phantom; mean target registration error; mutual information metric; rapid dynamic image registration; real-time 3-D US volumes; surgical navigation; two-step method; ultrasound; Computed tomography; Heart; Humans; Image registration; Imaging phantoms; Magnetic resonance imaging; Medical treatment; Navigation; Surgery; Ultrasonic imaging; Beating heart surgery; diagnosis; image-guided cardiac surgery; multimodality image registration; mutual information; Electrocardiography; Four-Dimensional Computed Tomography; Heart; Humans; Image Processing, Computer-Assisted; Linear Models; Magnetic Resonance Imaging; Male; Models, Cardiovascular; Phantoms, Imaging; Reproducibility of Results; Surgery, Computer-Assisted; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2009.2024684
  • Filename
    5071224