• DocumentCode
    1070299
  • Title

    Traceability and Verification of Interharmonic Generators in Support of Low-Frequency Immunity Testing (IEC61000-4-13)

  • Author

    Wright, Paul S. ; Clarkson, Paul

  • Author_Institution
    Nat. Phys. Lab., Teddington
  • Volume
    58
  • Issue
    4
  • fYear
    2009
  • fDate
    4/1/2009 12:00:00 AM
  • Firstpage
    1059
  • Lastpage
    1064
  • Abstract
    A description of the interference immunity testing of electrical products is given, and the need for traceable calibration methods of the associated testing generators is described. A presentation of three analysis techniques to verify the respective testing modes of immunity testing generators is given, together with typical uncertainties. A deconvolution method developed for the phase characterization of the analog-to-digital converter (ADC) used in this work is reported. A least squares algorithm for the piecewise analysis of the International Electrotechnical Committee (IEC) flat-top waveform is presented in the Appendix.
  • Keywords
    IEC standards; analogue-digital conversion; immunity testing; interference (signal); least squares approximations; power apparatus; test equipment; IEC61000-4-13 immunity standard; International Electrotechnical Committee; analog-to-digital converter; associated testing; electrical products; flat-top waveform; interharmonic generators; least squares algorithm; low-frequency immunity testing; traceable calibration methods; Analog-to-digital converter (ADC) characterization; deconvolution; electromagnetic compatibility (EMC); harmonic analysis; interharmonics; least squares methods; power quality;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2008.2010678
  • Filename
    4752780