• DocumentCode
    1072398
  • Title

    Dynamic Current Density of the Disk Electrode Double-Layer

  • Author

    Behrend, Matthew R. ; Ahuja, Ashish K. ; Weiland, James D.

  • Author_Institution
    Southern California Univ., Los Angeles
  • Volume
    55
  • Issue
    3
  • fYear
    2008
  • fDate
    3/1/2008 12:00:00 AM
  • Firstpage
    1056
  • Lastpage
    1062
  • Abstract
    With applied potential, the current distribution at the surface of a disk electrode is spatially nonuniform and time dependent. This distribution is important to control in applications that desire a uniform current density profile or minimal corrosion. We examine the current density profile of a capacitive disk electrode subjected to a voltage-step using finite element analysis software to solve the system of partial differential equations. In detailed analyses we show quantitatively that the current density shifts from peripheral enhancement to near-uniformity following 1/2 of the lumped element time constant. As charging continues, the current density is slightly enhanced in the central region. We present curves for the evolution of local ldquotime constantsrdquo as time progresses and calculate their effective values. The model is intended to be the basis of future work to control the corrosion profile of biologically implantable electrodes of arbitrary shape. Data suggest a means to control corrosion by retarding the edges of a stimulus pulse. Additionally, smaller electrodes may be more effective in fully utilizing surface area for charge transfer due to their shorter time constants.
  • Keywords
    biomedical electrodes; charge exchange; corrosion; current density; current distribution; electrochemical electrodes; finite element analysis; partial differential equations; patient treatment; biologically implantable electrodes; capacitive disk electrode; charge transfer; corrosion control; current distribution; disk electrode double-layer; dynamic current density; finite element analysis software; partial differential equations; Application software; Corrosion; Current density; Current distribution; Electrodes; Evolution (biology); Finite element methods; Partial differential equations; Shape control; Voltage; Current density; double layer; electrochemical processes; implantable electrodes; microelectrodes; Computer-Aided Design; Electric Impedance; Electrodes, Implanted; Electromagnetic Fields; Equipment Design; Equipment Failure Analysis; Microelectrodes; Surface Properties;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2008.915723
  • Filename
    4454033