Abstract :
This paper studies a novel method to compensate for respiratory and peristaltic motions in abdominal dynamic contrast enhanced magnetic resonance imaging. The method consists of two steps: 1) expiration-phase “template” construction and retrospective gating of the data to the template; and 2) nonrigid registration of the gated volumes. Landmarks annotated by three experts were used to directly assess the registration performance. A tri-exponential function fit to time intensity curves from regions of interest was used to indirectly assess the performance. One of the parameters of the tri-exponential fit was used to quantify the contrast enhancement. Our method achieved a mean target registration error (MTRE) of 2.12, 2.27, and 2.33 mm with respect to annotations by expert, which was close to the average interobserver variability (2.07 mm). A state-of-the-art registration method achieved an MTRE of 2.83-3.10 mm. The correlation coefficient of the contrast enhancement parameter to the Crohn´s disease endoscopic index of Severity (r = 0.60, p = 0.004) was higher than the correlation coefficient for the relative contrast enhancement measurements values of two observers (r(Observer1) = 0.29, p = 0.2; r(Observer2) = 0.45, p = 0.04). Direct and indirect assessments show that the expiration-based gating and a nonrigid registration approach effectively corrects for respiratory motion and peristalsis. The method facilitates improved enhancement measurement in the bowel wall in patients with Crohn´s disease.
Keywords :
biomedical MRI; diseases; image registration; medical image processing; motion compensation; motion control; motion measurement; patient diagnosis; pneumodynamics; Crohn´s disease endoscopic index of severity; MRI motion correction; abdominal MRI; abdominal magnetic resonance imaging; average interobserver variability; contrast enhancement parameter correlation coefficient; direct registration performance assessment; distance 2.07 mm; distance 2.12 mm; distance 2.27 mm; distance 2.33 mm; distance 2.83 mm to 3.10 mm; dynamic contrast MRI; dynamic contrast magnetic resonance imaging; enhanced MRI; enhanced magnetic resonance imaging; expert-annotated landmark; expiration-based gating approach; expiration-phase motion correction; expiration-phase template construction; free-breathing MRI; free-breathing magnetic resonance imaging; image registration method MTRE; magnetic resonance imaging motion correction; mean target registration error; nonrigid gated volume registration; nonrigid registration approach; patient bowel wall; peristaltic motion compensation; region of interest; relative contrast enhancement measurement values; respiratory motion compensation; template-based motion correction; template-directed retrospective data gating; time intensity curves; triexponential fit; triexponential function; Biomedical measurement; Colon; Diseases; Dynamics; Magnetic resonance imaging; Observers; Crohn’s disease; Crohn´s disease (CD); image registration; medical image processing; organ motion; peristalsis; susceptibility effect;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2014.2385307
Filename :
6995953
Link To Document :
بازگشت