Testing of Electrical Machine Stator Coils Using Sharp-Fronted Impulse Voltage
Author
Dhariwal, R.S. ; Yang, S.J.
Author_Institution
Department of Electrical and Electronic Engineering Heriot-Watt University Edinburgh, Scotland U.K.
Issue
4
fYear
1984
Firstpage
350
Lastpage
353
Abstract
This paper presents test results for assessing the impulse breakdown level of high voltage electrical machine stator coils, using a voltage surge with a risetime of the order of 0.1 ¿s. It was found that the difference between the voltage applied to the impulse generator before triggering and the peak voltage applied to the coil terminal changed dramatically and was a clear indication of breakdown.
Keywords
Breakdown voltage; Circuit testing; Coils; DH-HEMTs; Impulse testing; Machine windings; Power cables; Power system transients; Stators; Surges;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/TEI.1984.298810