DocumentCode :
1074199
Title :
Volt-ampere rating of air-core superconducting power transformers
Author :
Kataoka, Teruo ; Yamaguchi, Hiroshi ; Sato, Yukihiko ; Hayashi, Shin-Ichi ; Morimoto, Hajime
Author_Institution :
Tokyo Inst. of Tech., Japan
Volume :
29
Issue :
6
fYear :
1993
fDate :
11/1/1993 12:00:00 AM
Firstpage :
3592
Lastpage :
3594
Abstract :
The authors point out that air-core superconducting power transformers have the potential of serving not only as power transformers but also as shunt reactors when used in power transmission systems having large capacitances. Here, the rated primary volt-amperes, volt-amperes as a shunt reactor, and related quantities are analyzed and their relations to the magnetic coupling factor and magnetizing reactance of the transformer are clarified
Keywords :
power transformers; superconducting devices; air-core superconducting power transformers; large capacitances; magnetic coupling factor; magnetizing reactance; power transmission systems; rated primary volt-amperes; shunt reactors; Capacitance; Couplings; Inductors; Magnetic analysis; Power transformers; Power transmission; Shunt (electrical); Superconducting magnets; Superconducting transmission lines; Voltage transformers;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.281240
Filename :
281240
Link To Document :