• DocumentCode
    1075018
  • Title

    Monte Carlo simulations of shielded MR head

  • Author

    Torabi, Adam F. ; Batra, Sharat

  • Author_Institution
    Digital Equipment Corp., Shrewsbury, MA, USA
  • Volume
    29
  • Issue
    6
  • fYear
    1993
  • fDate
    11/1/1993 12:00:00 AM
  • Firstpage
    3823
  • Lastpage
    3825
  • Abstract
    A 2-D micromagnetic model is developed to predict performance of soft adjacent layer biased shielded magnetoresistive (MR) head. A Monte Carlo method is used to predict MR head performances such as isolated pulse amplitude, PW50 and pulse amplitude asymmetry versus critical process parameters
  • Keywords
    Monte Carlo methods; magnetic heads; magnetic recording; magnetic thin film devices; magnetisation; magnetoresistive devices; 2D micromagnetic model; Monte Carlo simulations; PW50; critical process parameters; isolated pulse amplitude; magnetisation distribution; magnetoresistive head; pulse amplitude asymmetry; shielded MR head; soft adjacent layer biased head; Anisotropic magnetoresistance; Demagnetization; Distributed computing; Magnetic anisotropy; Magnetic flux; Magnetic heads; Magnetic recording; Magnetization; Micromagnetics; Perpendicular magnetic anisotropy;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.281311
  • Filename
    281311