DocumentCode :
10754
Title :
Linearity and Shift Invariance for Quantitative Magnetic Particle Imaging
Author :
Kuan Lu ; Goodwill, P.W. ; Saritas, E.U. ; Bo Zheng ; Conolly, S.M.
Author_Institution :
Dept. of Bioeng., Univ. of California, Berkeley, Berkeley, CA, USA
Volume :
32
Issue :
9
fYear :
2013
fDate :
Sept. 2013
Firstpage :
1565
Lastpage :
1575
Abstract :
Magnetic Particle Imaging (MPI) is a promising tracer imaging modality that employs a kidney-safe contrast agent and does not use ionizing radiation. MPI already shows high contrast and sensitivity in small animal imaging, with great potential for many clinical applications, including angiography, cancer detection, inflammation imaging, and treatment monitoring. Currently, almost all clinically relevant imaging techniques can be modeled as systems with linearity and shift invariance (LSI), characteristics crucial for quantification and diagnostic utility. In theory, MPI has been proven to be LSI. However, in practice, high-pass filters designed to remove unavoidable direct feedthrough interference also remove information crucial to ensuring LSI in MPI scans. In this work, we present a complete theoretical and experimental description of the image artifacts from filtering. We then propose and validate a robust algorithm to completely restore the lost information for the x-space MPI method. We provide the theoretical, simulated, and experimental proof that our algorithm indeed restores the LSI properties of MPI.
Keywords :
biomedical MRI; cancer; filtering theory; high-pass filters; kidney; magnetic particles; medical image processing; patient monitoring; sensitivity; angiography; cancer detection; clinical applications; clinically relevant imaging technique; diagnostic utility; high-pass filters; image artifacts; inflammation imaging; kidney-safe contrast agent; linearity invariance; quantitative magnetic particle imaging; sensitivity; shift invariance; small animal imaging; tracer imaging modality; treatment monitoring; unavoidable direct feedthrough interference; x-space MPI method; Harmonic analysis; Image reconstruction; Large scale integration; Magnetic resonance imaging; Nanoparticles; Power harmonic filters; Angiography; direct current (dc) recovery; direct feedthrough; filtering; interference; linearity and shift invariance; magnetic particle imaging; Acoustics; Algorithms; Carotid Arteries; Carotid Stenosis; Computer Simulation; Contrast Media; Diagnostic Imaging; Fourier Analysis; Humans; Magnetite Nanoparticles; Models, Biological; Models, Theoretical; Phantoms, Imaging;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2013.2257177
Filename :
6494648
Link To Document :
بازگشت