• DocumentCode
    1075730
  • Title

    Determination of the Zero-Field Position in an Insulating Film by Thermally Stimulated Surface Potential Measurement in the Presence of a Temperature Gradient

  • Author

    Iwamoto, M. ; Kato, K. ; Hino, T.

  • Author_Institution
    Department of Electrical and Electronic Engineering
  • Issue
    4
  • fYear
    1987
  • Firstpage
    413
  • Lastpage
    417
  • Abstract
    A new technique for measuring the zero-field position in an insulating film is proposed. The technique consists of thermally stimulated surface potential measurement in the presence of a constant temperature gradient (TG-TSSP measurement) and it does not depend on sample thickness. Using a low-density polyethylene (LDPE) film having thickness d= 0.3 mm, the zero-field position vs. collecting voltage characteristic was measured and the electric field in the sample was determined.
  • Keywords
    Battery charge measurement; Current measurement; Dielectrics and electrical insulation; Electric variables measurement; Electrodes; Lamps; Position measurement; Space charge; Temperature measurement; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/TEI.1987.298901
  • Filename
    4081434