DocumentCode
1075863
Title
Calibration of DDS servo tracking error signals
Author
Taussig, Carl ; Elder, Rich
Author_Institution
Hewlett-Packard Lab., Palo Alto, CA, USA
Volume
29
Issue
6
fYear
1993
fDate
11/1/1993 12:00:00 AM
Firstpage
4053
Lastpage
4055
Abstract
A test apparatus is described which allows precise offtrack positioning of digital data storage (DDS) heads. This apparatus is used for calibration of tracking error signals (TESs). In addition, more detailed measurements were made of the writing and offtrack reading characteristics of DDS heads and a simple model was developed based on these measurements which successfully predicts TES vs. offtrack displacement
Keywords
calibration; digital audio tape; magnetic heads; magnetic recording; magnetic tape storage; position control; servomechanisms; DDS servo tracking error signals; DDS tape drive; TES; calibration; digital audio tape; digital data storage heads; offtrack displacement; offtrack positioning; offtrack reading characteristics; test apparatus; writing characteristics; Calibration; Frequency; Laser modes; Magnetic heads; Position measurement; Predictive models; Servomechanisms; Testing; Tracking; Writing;