DocumentCode
1077666
Title
Prediction of flashover voltage of non-ceramic insulators under contaminated conditions
Author
Venkataraman, S. ; Gorur, R.S.
Author_Institution
Dept. of Electr. Eng., Arizona State Univ., Tempe, AZ
Volume
13
Issue
4
fYear
2006
Firstpage
862
Lastpage
869
Abstract
This paper describes the development of a theoretical model to predict flashover voltage of nonceramic insulators. The model is based on reignition and arc constants that have been derived from electric field simulations and experimental data of flashover voltage and surface resistance measurements. New and field-aged silicone rubber and ethylene propylene diene monomer rubber samples were evaluated. A good correlation of the calculations from the model with experimental data has been demonstrated
Keywords
ageing; ethylene-propylene rubber; flashover; insulator contamination; silicone rubber; surface resistance; ageing; arc constant; electric field simulation; ethylene propylene diene monomer rubber sample; flashover voltage measurement; nonceramic insulator contamination; reignition; silicone rubber; surface resistance measurement; Ceramics; Dielectrics and electrical insulation; Flashover; Plastic insulation; Pollution; Polymers; Rubber; Surface contamination; Surface resistance; Voltage;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2006.1667747
Filename
1667747
Link To Document