  • Abstract
    This paper describes the development of a theoretical model to predict flashover voltage of nonceramic insulators. The model is based on reignition and arc constants that have been derived from electric field simulations and experimental data of flashover voltage and surface resistance measurements. New and field-aged silicone rubber and ethylene propylene diene monomer rubber samples were evaluated. A good correlation of the calculations from the model with experimental data has been demonstrated
  • Keywords
    ageing; ethylene-propylene rubber; flashover; insulator contamination; silicone rubber; surface resistance; ageing; arc constant; electric field simulation; ethylene propylene diene monomer rubber sample; flashover voltage measurement; nonceramic insulator contamination; reignition; silicone rubber; surface resistance measurement; Ceramics; Dielectrics and electrical insulation; Flashover; Plastic insulation; Pollution; Polymers; Rubber; Surface contamination; Surface resistance; Voltage;