Title :
Salt-Fog Pollution Test-A Modification to Suit Natural Conditions
Author :
Nandagopal, M.R. ; Gopalakrishna, H.V.
Author_Institution :
Department of High Voltage Engineering, Indian Institute of Science, Bangalore, India
fDate :
6/1/1973 12:00:00 AM
Abstract :
Salt-fog tests as per International Electrotechnical Commission (IEC) recommendations were conducted on stationtype insulators with large leakage lengths. Later, tests were conducted to simulate natural conditions. From these tests, it was understood that the pollution flashover would occur because of nonuniform pollution layers causing nonuniform voltage distribution during a natural drying-up period. The leakage current during test conditions was very small and the evidence was that the leakage current did not play any significant role in causing flashovers. In the light of the experimental results, some modification of the test procedure is suggested.
Keywords :
Flashover; IEC; Insulation testing; Insulator testing; Pollution; Power generation; Sea surface; Surface contamination; System testing; Voltage;
Journal_Title :
Electrical Insulation, IEEE Transactions on
DOI :
10.1109/TEI.1973.299259