Title :
Electrical Breakdown in a Cold Cathode Vacuum Diode
Author_Institution :
Sandia Laboratories, the Sandia Corporation, Albuquerque, N. Mex. 87115
fDate :
6/1/1974 12:00:00 AM
Abstract :
A 50-ns pulse generator is used to obtain time-correlated current-voltage relationships in the prebreakdown region for a long vacuum gap with cold planar electrodes. Analysis of data indicates several sequential stages occur. These stages include an initial quiet stage of voltage increase without interelectrode current, a microdischarge stage, a field emission stage, a space-charge controlled stage, and a final low-impedance stage where the current becomes sustaining. Electrical breakdown of the gap is considered in terms of a positive ion front moving from the anode.
Keywords :
Anodes; Cathodes; Current density; Diodes; Electric breakdown; Electrodes; Ionization; Plasmas; Vacuum breakdown; Voltage;
Journal_Title :
Electrical Insulation, IEEE Transactions on
DOI :