• DocumentCode
    1079197
  • Title

    A Maximum Likelihood Approach to Parallel Imaging With Coil Sensitivity Noise

  • Author

    Raj, Ashish ; Wang, Yi ; Zabih, Ramin

  • Author_Institution
    Cornell Univ., Ithaca
  • Volume
    26
  • Issue
    8
  • fYear
    2007
  • Firstpage
    1046
  • Lastpage
    1057
  • Abstract
    Parallel imaging is a powerful technique to speed up magnetic resonance (MR) image acquisition via multiple coils. Both the received signal of each coil and its sensitivity map, which describes its spatial response, are needed during reconstruction. Widely used schemes such as SENSE assume that sensitivity maps of the coils are noiseless while the only errors are in coil outputs. In practice, however, sensitivity maps are subject to a wide variety of errors. At first glance, sensitivity noise appears to result in an errors-in-variables problem of the kind that is typically solved using total least squares (TLSs). However, existing TLS algorithms are in general inappropriate for the specific type of block structure that arises in parallel imaging. In this paper, we take a maximum likelihood approach to the problem of parallel imaging in the presence of independent Gaussian sensitivity noise. This results in a quasi-quadratic objective function, which can be efficiently minimized. Experimental evidence suggests substantial gains over conventional SENSE, especially in nonideal imaging conditions like low signal-to-noise ratio (SNR), high g-factors and large acceleration, using sensitivity maps suffering from misalignment, ringing, and random noise.
  • Keywords
    Gaussian noise; biomedical MRI; coils; image denoising; image reconstruction; maximum likelihood estimation; medical image processing; random noise; Gaussian sensitivity noise; SENSE; coil sensitivity noise; errors-in-variables problem; g-factors; image reconstruction; magnetic resonance image acquisition; maximum likelihood approach; parallel imaging; quasiquadratic objective function; random noise; sensitivity maps; signal-to-noise ratio; spatial response; Acceleration; Biomedical imaging; Coils; Image reconstruction; Least squares methods; Magnetic noise; Magnetic resonance; Magnetic resonance imaging; Radiology; Signal to noise ratio; Magnetic resonance (MR); SENSE; maximum likelihood (ML); parallel imaging; total least squares (TLSs); Algorithms; Artifacts; Brain; Computer Simulation; Equipment Failure; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Likelihood Functions; Magnetic Resonance Imaging; Models, Biological; Models, Statistical; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Transducers;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2007.897364
  • Filename
    4280897