DocumentCode
1079208
Title
Test Methods Useful in Determining the Wet Voltage Capability of Polymer Insulator Systems after Lime Related Outdoor Exposures
Author
Niemi, Randolph G. ; Orbeck, Tor
Author_Institution
Dow Corning Corporation, Midland, Mich.
Issue
3
fYear
1974
Firstpage
102
Lastpage
108
Abstract
The use of an HV fog chamber in conjunction with a variety of environmental exposures to study degradation in the surface properties of polymer systems and how this affects wet electrical insulation is dealt with. Emphasis is placed on studying the conditions for leakage current inception and further current development leading to a flashover condition. The relationship between surface current, time, and voltage are plotted graphically and discussed.
Keywords
Dielectrics and electrical insulation; Flashover; Insulator testing; Leakage current; Plastic insulation; Polymers; Stability; Surface contamination; System testing; Voltage;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/TEI.1974.299300
Filename
4081823