Robotic Adherent Cell Injection for Characterizing Cell–Cell Communication
Author
Jun Liu ; Siragam, Vinayakumar ; Zheng Gong ; Jun Chen ; Fridman, Michael D. ; Leung, Clement ; Zhe Lu ; Changhai Ru ; Shaorong Xie ; Luo, JianChao ; Hamilton, Robert M. ; Yu Sun
Author_Institution
Dept. of Mech. & Ind. Eng., Univ. of Toronto, Toronto, ON, Canada
Volume
62
Issue
1
fYear
2015
fDate
Jan. 2015
Firstpage
119
Lastpage
125
Abstract
Compared to robotic injection of suspended cells (e.g., embryos and oocytes), fewer attempts were made to automate the injection of adherent cells (e.g., cancer cells and cardiomyocytes) due to their smaller size, highly irregular morphology, small thickness (a few micrometers thick), and large variations in thickness across cells. This paper presents a robotic system for automated microinjection of adherent cells. The system is embedded with several new capabilities: automatically locating micropipette tips; robustly detecting the contact of micropipette tip with cell culturing surface and directly with cell membrane; and precisely compensating for accumulative positioning errors. These new capabilities make it practical to perform adherent cell microinjection truly via computer mouse clicking in front of a computer monitor, on hundreds and thousands of cells per experiment (versus a few to tens of cells as state of the art). System operation speed, success rate, and cell viability rate were quantitatively evaluated based on robotic microinjection of over 4000 cells. This paper also reports the use of the new robotic system to perform cell-cell communication studies using large sample sizes. The gap junction function in a cardiac muscle cell line (HL-1 cells), for the first time, was quantified with the system.
Keywords
adhesion; bioMEMS; biological specimen preparation; biomechanics; biomedical measurement; biomembrane transport; cancer; cardiology; mechanical contact; medical robotics; mouse controllers (computers); pipes; position control; HL-1 cell; accumulative positioning error compensation; adherent cell microinjection system; adherent cell size; adherent cell thickness variation; automated microinjection system; automatic adherent cell injection; automatic micropipette tip location; cancer cell injection; cardiac muscle cell line; cardiomyocyte injection; cell experiment; cell membrane contact detection; cell viability rate; cell-cell communication characterization; computer monitor; computer mouse clicking; embryo injection; gap junction function quantification; irregular adherent cell morphology; large cell sample size; micropipette tip-cell culturing surface contact detection; oocyte injection; quantitative cell evaluation; robotic adherent cell injection; robotic microinjection; robotic suspended cell injection; robotic system; success rate; system operation speed; Biomembranes; Computer architecture; Computers; Microprocessors; Microscopy; Robots; Surface treatment; Cell communication; drug testing; gap junction; microinjection; robotics; toxicology testing;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2014.2342036
Filename
6863643
Link To Document