Three-dimensional (3-D) reconstruction of the spine from a single X-ray image and prior vertebra models
Author
Novosad, Justin ; Cheriet, Farida ; Petit, Yvan ; Labelle, Hubert
Author_Institution
Ste.-Justine Hosp. Res. Center, Montreal, Que., Canada
Volume
51
Issue
9
fYear
2004
Firstpage
1628
Lastpage
1639
Abstract
The lateral bending test is routinely used by clinicians for the preoperative assessment of spinal mobility. The evaluation of bending motion is usually based on the qualitative analysis of a two-dimensional (2-D) antero-posterior X-ray image. The aim of this paper is to introduce a novel three-dimensional (3-D) reconstruction technique that is a prerequisite for the quantitative 3-D analysis of lateral bending motion. An algorithm was developed for the 3-D reconstruction of the spine from a single X-ray image. The X-ray is calibrated using a small calibration object and an explicit calibration algorithm. The information contained in the single X-ray is completed by registering a priori 3-D geometric models of individual vertebrae. Part of the error yielded by the 3-D/2-D registration is corrected by a vertebral alignment constraint that aims to minimize intervertebral dislocations. Three-dimensional models of 15 different scoliosis patients, obtained from a standard stereo-radiographic 3-D reconstruction, were used in simulation and validation experiments. Experimental results show that the new method is robust and accurate. With pessimistic levels of simulated noise, the average root mean square reconstruction error is 2.89 mm, which is appropriate for common clinical applications.
Keywords
bending; biomechanics; bone; diagnostic radiography; diseases; image motion analysis; image reconstruction; image registration; medical image processing; a priori 3-D geometric models; bending motion; calibration; image registration; intervertebral dislocations; lateral bending test; scoliosis patients; single X-ray image; spinal mobility; stereo-radiographic 3-D reconstruction; three-dimensional spine reconstruction; two-dimensional antero-posterior X-ray image; vertebra models; Calibration; Image analysis; Image motion analysis; Image reconstruction; Motion analysis; Solid modeling; Testing; Three dimensional displays; Two dimensional displays; X-ray imaging; Algorithms; Artificial Intelligence; Calibration; Cluster Analysis; Computer Simulation; Imaging, Three-Dimensional; Information Storage and Retrieval; Models, Biological; Models, Statistical; Pattern Recognition, Automated; Phantoms, Imaging; Radiographic Image Enhancement; Radiographic Image Interpretation, Computer-Assisted; Reproducibility of Results; Scoliosis; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Spine; Subtraction Technique;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2004.827537
Filename
1325823
Link To Document