• DocumentCode
    1079826
  • Title

    Comparison of degradations in radar system sensitivities due to TR tube and TR limiter

  • Author

    Sarkar, B.K.

  • Author_Institution
    Tata Institute of Fundamental Research, Bombay, India
  • Volume
    29
  • Issue
    5
  • fYear
    1982
  • fDate
    5/1/1982 12:00:00 AM
  • Firstpage
    931
  • Lastpage
    932
  • Abstract
    The degradation of radar system sensitivities due to the TR tube and the TR limiter are calculated. A general expression relating to the various parameters of the TR tube and the TR limiter and noise figure of the receiver is derived from the condition that the TR limiter will be more sensitive than the TR tube with keep-alive, KA. In particular, the TR limiter may be less sensitive than the TR tube with KA due to the higher insertion loss of the TR limiter. The much longer life of the TR limiter, however, may be the deciding factor for its use in a radar receiver.
  • Keywords
    Degradation; Electron tubes; Fault location; Insertion loss; Noise figure; Plasma temperature; Radar antennas; Semiconductor device noise; Temperature sensors; Tin;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1982.20803
  • Filename
    1482300