DocumentCode
1082649
Title
Amplifying medium characteristics in optimized 190 µm/195 µm DCN waveguide lasers
Author
Belland, Pierre ; Véron, Didier
Author_Institution
Centre d´´Etudes Nucleaires, Fontenay-Aux-Roses, France
Volume
16
Issue
8
fYear
1980
fDate
8/1/1980 12:00:00 AM
Firstpage
885
Lastpage
890
Abstract
Extensive study of the CW, dischaxge-pumped, DCN laser operating on the (2200-0910) 190 and 195 μm lines has been undertaken in order to develop a new source of radiation suitable for plasma diagnostics. The optimum values of the parameters of the discharge, the unsaturated gain, and the saturation intensity are given as a function of the tube diameter. Scaling laws predicting the maximum output power as a function of the tube dimensions and of the cavity loss are established. Such lasers compare favorably with optically pumped submillimeter lasers, since 250 mW are available from a 3 m long, 5 cm diameter waveguide DCN laser.
Keywords
CW lasers; Gas lasers; Submillimeter-wave lasers; Waveguide lasers; Electron tubes; Fault location; Optical losses; Optical pumping; Optical saturation; Optical waveguides; Plasma diagnostics; Power generation; Pump lasers; Waveguide lasers;
fLanguage
English
Journal_Title
Quantum Electronics, IEEE Journal of
Publisher
ieee
ISSN
0018-9197
Type
jour
DOI
10.1109/JQE.1980.1070587
Filename
1070587
Link To Document