• DocumentCode
    1082944
  • Title

    Ambulatory Estimation of Center of Mass Displacement During Walking

  • Author

    Schepers, H. Martin ; Van Asseldonk, Edwin H F ; Buurke, Jaap H. ; Veltink, Peter H.

  • Author_Institution
    Inst. for Biomed. Technol., Univ. of Twente, Enschede
  • Volume
    56
  • Issue
    4
  • fYear
    2009
  • fDate
    4/1/2009 12:00:00 AM
  • Firstpage
    1189
  • Lastpage
    1195
  • Abstract
    The center of mass (CoM) and the center of pressure (CoP) are two variables that are crucial in assessing energy expenditure and stability of human walking. The purpose of this study is to estimate the CoM displacement continuously using an ambulatory measurement system. The measurement system consists of instrumented shoes with 6 DOF force/moment sensors beneath the heels and the fore-feet. Moreover, two inertial sensors are rigidly attached to the force/moment sensors for the estimation of position and orientation. The estimation of CoM displacement is achieved by fusing low-pass filtered CoP data with high-pass filtered double integrated CoM acceleration, both estimated using the instrumented shoes. Optimal cutoff frequencies for the low-pass and high-pass filters appeared to be 0.2 Hz for the horizontal direction and 0.5 Hz for the vertical direction. The CoM estimation using this ambulatory measurement system was compared to CoM estimation using an optical reference system based on the segmental kinematics method. The rms difference of each component of the CoM displacement averaged over a hundred trials obtained from seven stroke patients was (0.020 plusmn 0.007) m (mean plusmn standard deviation) for the forward x-direction, (0.013 plusmn 0.005) m for the lateral y-direction, and (0.007 plusmn 0.001) m for the upward z-direction. Based on the results presented in this study, it is concluded that the instrumented shoe concept allows accurate and continuous estimation of CoM displacement under ambulatory conditions.
  • Keywords
    biomedical equipment; force sensors; gait analysis; high-pass filters; kinematics; low-pass filters; ambulatory estimation; ambulatory measurement system; center of mass displacement; center of pressure; force sensor; frequency 0.2 Hz; frequency 0.5 Hz; high-pass filter; human walking stability; inertial sensors; instrumented shoes; low-pass filter; moment sensor; optical reference system; position estimation; segmental kinematics method; Displacement measurement; Footwear; Force measurement; Force sensors; Humans; Instruments; Legged locomotion; Low pass filters; Optical filters; Stability; Acceleration; ambulatory; balance; center of mass (CoM); center of pressure (CoP); gait analysis; human walking; Biomechanics; Equipment Design; Gait; Humans; Middle Aged; Models, Biological; Postural Balance; Shoes; Stroke; Walking;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2008.2011059
  • Filename
    4760226