DocumentCode :
1083350
Title :
Efficiency Comparison of Voltage-Source and Current-Source Drive Systems for Medium-Voltage Applications
Author :
Suh, Yongsug ; Steinke, Juergen K. ; Steimer, Peter K.
Author_Institution :
ABB Switzerland Ltd., Turgi
Volume :
54
Issue :
5
fYear :
2007
Firstpage :
2521
Lastpage :
2531
Abstract :
This paper calculates and compares the efficiency and loss distribution in the three most popular state-of-the-art types of large motor drive systems: 1) current-source drive with active front-end rectifier; 2) current-source drive with 18-pulse thyristor rectifier; and 3) three-level voltage-source drive with 12-pulse/24-pulse diode rectifier. For converter systems with efficiencies better than 90%, it is suggested to calculate or measure the losses of all the components separately and add them up to calculate the total efficiency. A simple and accurate method of calculating switching losses for a current-source and voltage-source converter is proposed. Through the calculation and simulation of each loss factor such as switching losses, conduction losses, and snubber and filter losses, the three-level voltage-source drive system has been found to have the highest efficiency of 98.77% under the rated load of 1.6 MW.
Keywords :
AC motor drives; PWM power convertors; PWM rectifiers; switching convertors; thyristor convertors; AC motor drive; current-source drive system; diode rectifier; medium-voltage applications; power 1.6 MW; pulsewidth- modulated inverters; switching losses; thyristor rectifier; voltage-source drive system; AC motor drives; multilevel systems; pulsewidth-modulated inverters; solid-state rectifiers;
fLanguage :
English
Journal_Title :
Industrial Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0046
Type :
jour
DOI :
10.1109/TIE.2007.900352
Filename :
4285711
Link To Document :
بازگشت