• DocumentCode
    1085879
  • Title

    Test results of the Q1 quadrupoles for the CEBAF high resolution spectrometer

  • Author

    Gallet, B. ; Berriaud, C. ; Daël, A. ; Gelebart, J.C. ; Lesmond, C. ; Mayri, C. ; Thinel, J. ; Vernin, P.

  • Author_Institution
    Service Tech. de Cryogenie et de Magnetisme, CEA, Centre d´´Etudes Nucleaires de Saclay, Gif-sur-Yvette, France
  • Volume
    32
  • Issue
    4
  • fYear
    1996
  • fDate
    7/1/1996 12:00:00 AM
  • Firstpage
    2167
  • Lastpage
    2170
  • Abstract
    The 4 GeV/c high resolution spectrometers of the CEBAF experimental Hall A require two mirror imaged superconducting quadrupole magnets of cosine 2θ configuration. These magnets, built at Saclay, have the following parameters: 300 mm clear bore, 948 mm magnetic length, quadrupole field gradient 8.5 T/m with a 1×10-5 uniformity. The paper gives an overview of the design and describes construction technology and test results: coil dimensions, harmonics content, gradient measurement
  • Keywords
    accelerator magnets; electron accelerators; electron spectrometers; superconducting magnets; 300 mm; 4 GeV/c high resolution spectrometers; 948 mm; CEBAF high resolution spectrometer; Q1 quadrupoles; clear bore; coil dimensions; cosine 2&thetas; configuration; harmonics content; magnetic length; mirror imaged superconducting quadrupole magnets; quadrupole field gradient; uniformity; Boring; Coils; Conductors; Copper; Helium; Insulation; Spectroscopy; Steel; Superconducting magnets; Testing;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.508594
  • Filename