• DocumentCode
    1086327
  • Title

    An improved range-resolution pulse-echo technique by means of vectorial-network-analyzer-based frequency-domain testing

  • Author

    Bramanti, Mauro

  • Author_Institution
    IEI, CNR, Pisa, Italy
  • Volume
    41
  • Issue
    3
  • fYear
    1994
  • fDate
    5/1/1994 12:00:00 AM
  • Firstpage
    418
  • Lastpage
    420
  • Abstract
    A particular procedure is suggested to implement a high-range-resolution pulse-echo ultrasound technique by means of a frequency-domain exploration of the tested device and a successive Fourier inverse transformation of the measured data. The improvement with respect to conventional methods is estimated, and an experimental setup based on the use of a commercially available vectorial network analyzer is presented.<>
  • Keywords
    automatic test equipment; echo; flaw detection; frequency-domain analysis; inspection; network analysers; ultrasonic equipment; ultrasonic materials testing; US technique; frequency-domain testing; high-range-resolution; pulse-echo technique; successive Fourier inverse transformation; ultrasound technique; vectorial-network-analyzer; Bandwidth; Fourier transforms; Frequency domain analysis; Frequency measurement; Impedance measurement; Pulse measurements; Testing; Transducers; Ultrasonic imaging; Ultrasonic variables measurement;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.285480
  • Filename
    285480